Floor loading
Floors must be capable of bearing loads applied to them. There are two main types of structural load that are usually considered in the design of structural floors; live loads and dead loads:
- Dead loads include the weight of the building materials themselves, and are static and permanent. The dead load value is determined by adding together the weight of all permanently installed materials.
- Live loads are imposed on the building and are temporary and dynamic, such as the weight of occupants, furniture or anything else that can be moved.
The above describes the type of loads, in effect by the length of time they are likely to apply a force upon a floor structure, ie temporarily or over longer periods. Further to this it can be important to consider how the loads are applied at any point in time, for example over a small area of floor, over a larger area or in a line, for this certain terms are used.
- Concentrated loads (or point loads) are single loads that act over a relatively small area, they can be dead loads such as columns which apply a heavy force over a relatively small area, or live loads, such as people whose full weight applies a force over the area of their feet when standing up, or a table which applies forces from the weight of a table through the small area at the bottom of the table legs.
- Distributed loads (or surface loads) are loads that are exerted over a larger surface area, they are most likely to be dead loads such as such as the weight of floors and floor boards combined and spread over the area of the entire floor. The term can also be used to reflect different types of live loads also, for example if a person lies on the floor rather than stands they are employing weight distribution, that is to say their weight is distributed over the larger surface area of the whole body than just the area of their feet, if they were standing.
- Line loads as the term suggests are loads that are applied linearly, again these are most likely to be dead loads such as such as the weight of a wall spread in a line over a floor area, but can also be live loads if linear heavy objects are installed, such as a bookshelf. These may also be referred to as linear loads but often linear load is used with reference to electrical loads.
The heavy the load the more important it is for the load to be spread over a wider surface area. It the case of a timber floor it will be made up if floor joist running between walls and most likely then have floor boards which run perpendicular to the joists. This helps to spread or distribute any floor loads evenly across all of the floor joists, whether they are live loads or dead loads. To determine the minimum design values for strength of a floor, live and dead loads are added together.
In order to resist these loads, all elements of the floor must have the requisite strength and stiffness, typically determined by the maximum allowable deflection of the floor, i.e. how much, it will 'bend' under the maximum expected load.
Determining dead loads is relatively straight forward, however as live loads are changeable structural designs can only make a reasonable allowance for what is expected.
Allowing for higher live loads increases the flexibility of a building, but also increases the cost. For example, historically, UK office buildings have been designed and marketed with live loadings of 3.5–4.0 kN/m2, however, this may be an over-provision. 2.5 kN/m2 for floors above ground floor and 3.0 kN/m2 at, or below, ground floor over may be more appropriate, with 7.5 kN/m2 over 5% of the floor area to allow for future flexibility.
See Structural systems for offices for more information.
There may be particular problems in older buildings which have been adapted for modern uses, resulting in live loads that are far higher than was allowed for by the original design. For example, historic houses converted to office use where there may be very high storage or equipment loads. In the case of older buildings it is also important to consider how the age of any structural members may have been effected by age or damage for example through dry rot and specialst advice should be sought it issues appear.
[edit] Related articles on Designing Buildings
- Bearing capacity.
- Beam and block.
- Biaxial bending.
- Braced frame.
- Concept structural design of buildings.
- Dead loads.
- Finished floor level.
- Flooring.
- Gross floor area GFA.
- Lateral loads.
- Limit state design.
- Live loads.
- Load-bearing wall.
- Point load.
- Resilient flooring.
- Structural engineer.
- Types of floor.
- Types of structural load.
- Uniformly Distributed Load.
- Wind load.
Featured articles and news
Cladding remediation programmes, transparency and target date.
National Audit Office issue report on cladding remediation.
HBPT and BEAMS Jubilees. Book review.
Does the first Labour budget deliver for the built environment?
What does the UK Budget mean for electrical contractors?
Mixed response as business pays, are there silver linings?
A brownfield housing boost for Liverpool
A 56 million investment from Homes England now approved.
Fostering a future-ready workforce through collaboration
Collaborative Futures: Competence, Capability and Capacity, published and available for download.
Considerate Constructors Scheme acquires Building A Safer Future
Acquisition defines a new era for safety in construction.
AT Awards evening 2024; the winners and finalists
Recognising professionals with outstanding achievements.
Reactions to the Autumn Budget announcement
And key elements of the quoted budget to rebuild Britain.
Chancellor of the Exchequer delivers Budget
Repairing, fixing, rebuilding, protecting and strengthening.
Expectation management in building design
Interest, management, occupant satisfaction and the performance gap.
Connecting conservation research and practice with IHBC
State of the art heritage research & practice and guidance.
Innovative Silica Safety Toolkit
Receives funding boost in memory of construction visionary.
Gentle density and the current context of planning changes
How should designers deliver it now as it appears in NPPF.
Sustainable Futures. Redefining Retrofit for Net Zero Living
More speakers confirmed for BSRIA Briefing 2024.
Making the most of urban land: Brownfield Passports
Policy paper in brief with industry responses welcomed.
The boundaries and networks of the Magonsæte.